<-- nev left start -->

BOD Incubator

BOD Incubator
BOD Incubator
Product Specifications
  • BOD Incubator
  • Other
  • 230 V Volt (v)
  • Electrical
  • 230 Volt (v)
  • No
  • 5.0 °C to 60.0 °C Celsius (oC)
  • 5.0 °C to 60.0 °C Celsius (oC)
  • As per Requirement Inch (in)
  • As per Instruments size Kilograms (kg)
  • Blue
  • 1 Year
    Product Description

    Specifications

    • Temperature Range 5.0 °C to 60.0 °C. Accuracy +/- 0.1 °C. Uniformity +/- 1.0 °C
    • Temperature Display: Digital LED 3  digit, Resolution 0.1 deg C
    • Heating system: U shaped Nichrome wire heater in SS Sheathing.
    • Cooling system: Hermetically sealed CFC free Emerson compressor with R 134a refrigerant.
    • Air circulation: Flange Motor with Impeller and blower.
    • Interior Illumination for working Area.

    Construction

    • Double walled, gap between walls filled with PUF Insulation.
    • Standard Model: Stainless steel Mirror polished chamber and heavy gauge Powder- coated CRC exterior.
    • GMP Model: Stainless steel Mirror polished chamber and exterior of dull finish stainless steel.
    • Double door: Inner full Viewing door and outer door insulated with lock and key arrangement.
    • 3” Thick CFC Free Puff Insulation.
    • Stainless steel Trays. Adjustable Tray Height adjustment.
    • Unit Mounted on castor wheels with front lock arrangement.

    Control Panel

    • Micro processor based PID temp. Controller with auto tune facility for precise control of temperature.
    • Temp. Sensor: PT- 100.
    • Dedicated safety controller with separate sensor to cut off the supply in case of overshoot and undershoot of temperature giving audio visual alarm. ( Optional)
    • Recorder data bank to store and print set values , process values , date and time of master controllers with variable print time intervals (Optional)
    • PC Interface communication card with RS 485 for temperature and humidity control system ( Hardware only) ( optional)

     

    SafetyFeatures

    • Over heat temperature with alarm.
    • Electrical overload compressor cut-off.
    • Time delay for compressor switch on.
    • Electrical short circuit breaker.

    Utilities

    • Room temperature around machine preferably at 25 degree C.
    • Stabilized input voltage of 230V Ac, 50 Hz, and 20 Amps.
    • Water drains line with Nozzle to be provided at floor level.
    Trade Information
    • 01 Per Week
    • 1 Week
    • Contact us for information regarding our sample policy
    • Plastic wrap & Corrugated standard packaging
    • West Bengal, Uttarakhand, Uttar Pradesh, Tripura, Rajasthan, Manipur, Maharashtra, Madhya Pradesh, Jharkhand, Himachal Pradesh, Haryana, Goa, Gujarat, Daman and Diu, Dadra and Nagar Haveli, Delhi, Chandigarh, Chhattisgarh, Arunachal Pradesh, Andhra Pradesh
    Contact Us

    Patel Scientific Instruments Pvt Ltd Plot No.60,61- Abhishree Estate, Behind Vehpari Mahamandal, Nr. Ring Road Circle, Odhav, Ahmedabad, Gujarat, 382415, India
    Phone :+918045804391